The Megaco mib is as of yet not standardized and our implementation is based on draft-ietf-megaco-mib-04.txt. Almost all of the mib cannot easily be implemented by the megaco application. Instead these things should be implemented by a user (of the megaco application).
So what part of the mib is implemented? Basically the relevant statistic counters of the MedGwyGatewayStatsEntry.
7.2 Statistics counters
The implementation of the statistic counters is lightweight. I.e. the statistic counters are handled separately by different entities of the application. For instance our two transport module(s) (see megaco_tcp
and megaco_udp
) maintain their own counters and the ap